Contact Us

Leak Testing and Nitrogen Purging

...

This project is a three-year contract for leak testing services at different brownfield sites. The goal of the project is to ensure that the upgraded or expanded facilities meet joint integrity requirements without any leaks before the introduction of hydrocarbons.
The project includes the following scope of work:

  • Pre-engineering activities: The team will prepare procedures and leak test packs before starting the testing process. This will involve reviewing the facility design, determining the required testing methodology, and creating the necessary testing procedures and checklists.
  • System preparation: The team will work to prepare the system by cleaning, flushing, and verifying that all equipment and components are ready for testing.
  • Pressurization of the system: The team will pressurize the system and perform leak tests using appropriate methods and techniques to detect and locate any leaks.
  • Line walk downs and snoop test: The team will perform visual inspections and use leak detection tools such as snoop tests to verify the integrity of the entire system.
  • Safe de-pressurization: Once the testing is complete, the team will safely de-pressurize the system to ensure that it is safe to work on.
  • Purging prior to start-up: Finally, the team will purge the system to remove any remaining fluids or gases before the facility is ready for start-up.

The project requires a team of experienced technicians and engineers who can work safely and efficiently to complete the testing within the specified timeline. The team will work closely with the client to ensure that all testing requirements are met and that the facility is safe to operate.